For items I know for sure it exists, I saw it. Obviously 6 sides/block would be optimal but that can only happen with a single block, so it's not scalable, similarly 5 sides/block can only happen with 2 blocks, so the best you can get is 4 sides/block, meaning each controller block is connected to at most 2 others, i. The ME Controller is a block added by Applied Energistics 2. While hovering over an item that has a guide page, hold the W key to open the corresponding guide page. Most are so small that they don't even have their own Controller, which is called "Ad-Hoc. Release. A 3-block controller has 14 faces x 32 channels = 448 total channels. It serves like a base to processors added by the mod. For logistic pipes, you have xnet for automation, and you could rush integrated dynamics. This structure can be built in any cuboid, or size as long as the following Criteria are met. The controller can also transmit an unlimited number of channels through itself. a controller with infinite channels. . As far as I am aware those are the only restrictions. SSD can have as many of these ad-hoc networks as you want. Cheers!The ME Controller is a block added by the Applied Energistics 2 mod. • 22 days ago. Applied Energistics 2: ID Name : appliedenergistics2:item. In the network tool GUI of AE2 (access by right clicking an AE2 device on a ME network such as a cable), there is a title "network details", followed by "stored power" (0 RF [0 AE] , as there is no energy cell and I'm powering via tesseract), max power (16 kRF [8 kAE]), then a list of AE2 devices on the network. 3 Controlling the Network . Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. Top 1% Rank by size . i would suggest using a RFTools crafter to do a passive autocraft to keep stock of each level of essence (using drawers or something) as opposed to. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable and turn white. The maximum length of one axis of the multiblock is 7 blocks; An ME Controller can have 2 adjacent blocks in at most 1 axis; Rule #3 essentially means that, of the 3 axes (north/south, east/west, up/down), only one of those axes can have 2 controller blocks on both sides of any given controller and that the other axes may only have one. No cards, no items, only. But it also means that they connect even if you don't want them to and you can get cross connections. Master_Builder_800, GreekAnalyzer, adamich and 1 other person. (16x16 area) Describe the feature: +1 range from the controller. The ME Controller allows you to start a ME network within minecraft. Manyullyn 前回宣言した通り、今回からME倉庫の構築を目標として. Different devices can be connected to the ME Network, such as an ME Drive, for the storage of items, or an ME. Im happy to present you MyModpackList a site inspired by MyAnimeList and allows you to make your own list of modpacks you want to. The ME Molecular Assembler Chamber must be a minimum of 3x3x3 block cube. The ME Wireless Access Point is a block added by the Applied Energistics 2 mod. ME Controllers are thus disabled as a result, so anything relating to the. The ME System is used for. The structure must be an ME network with a number of Spatial Pylons which define the target region. More than enough channels. . Do what you normally would to join 2 p2ps and see whether it works. After making the room proper, I discovered that the drawer controller can control drawers that are 12 blocks away from the controller in any direction. With auto crafting accessible via a p2p connected to the yellow network. I was partly going for wanting it to look a bit diff anyhow. The blocks you see in my screenshots are the futura blocks you're talking about, but yea that's an idea, finally I just added a shape in the center of my room. Items like the Interface, Import Bus, ME Drive block, etc all consume 1 channel per device. As long as all rules are followed and powered, the controller should glow and cycle colors. Therefore it at first seems that the most efficient use of disk space would be to use 1k disks because the index would be as small as it could be. I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. But in Minecraft you need to. The crafting CPU as a multi-block only requires a single channel for the entire. I'm going to try adding another ME Controller to increase the channel limit, but. them outside the network. I wouldn't suggest a turbine until you can use the power of a max size one which is 80 blades, uses 2000 mb/t of steam, and produces around 27k RF/t depending on the power multiplier in the configs. The rules for a valid SCS are, A minium size of 3x3x3 ( this will capture a single block. cfg" and open -> Find the following ->. When teh number stops changing, or you get bored, start the craft :P. com, stoneblock version is 1. Key things to remember about channels: Each side of a controller block can support 32 channels. 1. The island bridges were ~80% full. 1. Hilbert controller has 510, so you're looking at almost exactly 30% more faces. I'm not a big fan of watching 30 minute tutorial videos to get started in a mod, so here's some basics: The only things you absolutely need for an ME network are some kind of power source and an ME controller. This can be useful to move a multi-block stucture or a processing machine set-up. so you can go Energy Acceptor (1 channel) -> Main network cable->quartz cable->transport cable. You can't have more than 1 controller on a network, but adjacent controllers form a multiblock, allowing more sides. Now your next recipe should be named item 1 + the next 8 components = named item 2. By AlgorithmX2. I agree, you can pretty much do everything a well equipped base needs with 1 controller and a few dense cables (or p2p, if you want). AE2 ME Controller Keeps Flickering. Join. Theinventor10. Applied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). Normally in the inside of a corner you can't get 32 channels out of each face as if you place a cable there it'll connect to both faces and only let 32 channels through itself, wasting anywhere from 32 channels in a regular corner, and 128 in. P2P Tunnel or "Point to Point Tunnels" are a versatile configurable system to move items / redstone / power / and fluids from one location to another though an existing ME Network without storage. 10 now I'm trying to replicate my old setup without luck. This afternoon i'm going to aim to make the most potential one using smart cable only to see what size a good automated crafting AE system can do with only smart cable (#Challenge). (ME interface, screens, autocrafters, anything) Each side of your ME Controller block has 32 available channels. Applied Energistics 2 (以下AE2)上級者を目指すためにいろいろとテストしてわかった他のMODにはないAE2独自の輸送特性についてのメモも含めた解説記事となります. Medium Spatial Cell which can store 16x16x16 regions of space. An instant connection between any two points on an ME Network. 2 One route to the controller: 1. It accepts energy in from most sources, such as EU and MJ and provides it to the machines connected to it. 0. The ME Controller is a block added by Applied Energistics and is the heart of ME Networks. Once it's in. Alternative, use a level controller pointing to the machine or an export bus/interface with a crafting card set to make the item you want. ControllerLimits (initially -> false) - allows you to install several controllers in the same network (in the false state, allows you to set an unlimited number of controllers);. There is a way to circumvent this. Join. Two ME Controller blocks make a 1 x 2 multiblock structure which has a total of ten faces, or 80 channels with regular ME Cable. However!At the moment, my ME System is located underneath my Incense Altar Pyramid (Max size), but I am considering moving after I find a new base location. Blocking mode for sub-networks point main network toward sub net for 1:1 or point sub networks toward the main interface for up to 5 sub networks per interface. Maximum size of the ME Controller multiblock is now configurable. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. (The controller doesn't handle data. it can be hollow, but be careful, some of the outer ones will deactivate, you will have to add holes. It can be small or big, but only one per network. One thing you will need to know when making a multiblock is that each controller can touch no more than 3 other controllers to remain valid. 2 Steve's First Network . A part of the MAC multi-block that stored encoded patterns. So within rule 2, there are 6 corner blocks (max 3 connections), 60. 7. You might as well just make a converter for whatever systems. Smart, covered, or normal ME cable = 8 channels carrying capacity. 32 in dense ones. You are correct. . ). Void junk/non stackable items or store. Its theme is centered around the concept of converting matter into energy and vice versa, to store and transport your items and fluids instantaneously!Your Applied Energistics storage system will probably not work without a ME Controller. MK234. Is AE2 storage infinite, or is it limited? AE 1 had infinite storage, as you could connect as many ME Drives as you wanted to a controller. The ME Controller is the core machine required for any Applied Energistics network. As far as exceeding the 7-consecutive-controller-blocks restriction is concerned, I think its hard coded, although you CAN turn off channels in the config file (networkfeatures field) - if your goal is just to have more channels. 6. When taken by itself, the ME Controller does nothing. B:Channels=true. 7. For every 32 drives, you'll need one P2P tunnel on the controller. This shape, a fractal called a Hilbert Curve, has the largest known number of. " Such networks are limited to only 8 Channels. ・まとめ AE2のみでも、各種素材要求物の自動化や実質容量を劇的に増やすこともできる。単体導入や、MODPackに入っていた場合でも安心。 が、強いこだわりや複雑な施設による負荷を避けたいなら、アドオンの「AE2 Stuff」を同時に導入すると、面倒な自動設備を数ブロックに圧縮できるため. More than enough channels. A single block controller could take in 3 dense cables and output 3 dense cables, meaning you would have access to 3 * 32 * 32=3072 channels from a single block controller. manually mine. 2; Forge; Nov 7, 2023;. The mod includes a. 0:00 / 9:22. 4. An import bus takes a channel, a disk drive takes a channel, a terminal takes a channel, every machine takes up just one channel. If you make the line the p2p ports are on connect to a controller, you can also connect the p2p face of the p2p port onto the same controller, allowing you to use the controller to connect. It also has its own power generator in the form of Vibration Chambers. e. size unless you do something like the last pic. jar; Forge Version:14. The CPU must contain at least 1 storage component. The controller is a multiblock structure that follows a few. I then use an Ender IO power monitor to turn the reactor on and off. More posts you may likeDrawer A. The developers of the pack have turned off AE2's channel system, if you'd like to re-enable it, consider the following: Find modpack's files -> Open config folder -> Find "AppliedEnergistics2. Not sure if this has been done before but this is how I do my molecular assemblers. About 1/4 machine automation, 1/4 autostocking, and the rest crafting interfaces. 1. 2 In Conclusion . Yes, an ME Interface can use 6 MAs at the same time without other augments. You always have hoppers as well. like it doesnt exist. When used in conjunction with the Quantum Link Chamber, the block's texture and shape will connect with the surrounding blocks, forming the Quantum Network Bridge. 1. The main feature of Applied Energistics 2 is the ME Network ( pronounced Emm-Eee and stands for Matter Energy ), which is a set of connected blocks, and cables grouped into a system, where storage, power and functions cooperate between multiple components. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits (initially -> false) - allows you to install several. [deleted] • 7 yr. it's one big line. 2. When you create a P2P into a dense cable, you are converting 32 channels from 1 facing into 1 channel. ). If you need more than 8 channels, you need a ME Controller. They are usually very limited in scope and rarely directly accessed by the player (mostly for automation). The ME Controller was only really necessary for when there are channels. Then a single stand of smart cable to wherever I'm working at. Crafting CPU. No idea what you're attempting but from the explanation I don't think it's possible. That means it can transfer 16krf/t. Il s'agit d'une version nouvelle et améliorée du mod Applied Energistics original. To fix this people build it in a box shape with only the corners of the box, or if you're like me, a line. I went into a bit more detail a few minutes before you posted your question. Learn P2P Tunnels. The ME Controller is a block added by the Applied Energistics 2 mod. Any data-storing or data-using device needs a channel. All the autocrafting bits and bobs are still there and operational. r/feedthebeast. When right clicked, the Controller's GUI will display the state of the controller, the total energy stored, the energy draw of the network, and the devices. What I don't like about AE2's CPU is you need 3 parts: the CPU, an ME interface, and a molecular. In practice the amount of channels you actually need comes down to how much you intend to solve with AE2 and the modpack you are playing. AE2 has a 'spatial storage' component. Applied Energistics 2 (AE2) is a comprehensive mod for Minecraft that introduces a unique approach to in-game inventory management. For any more channels you need a controller but if your just using a couple drives ad hoc should work perfectly for nowApplied Energistics 2 is a mod created by AlgorithmX2 designed to compactly store items in a digital network called Matter Energy, or ME (pronounced Emm-Eee). With the way tags and flattening works, it also would not be of much use. Read below for info and updates on the s. If you have Immersive Engineering, you can get a mod, called ZettaIndustries, that has ME cables which can span a long way and give you stable connection through unloaded chunks. Each face of the Controller has 32 Channels, and items using channels trace the shortest path they can back to the Controller. Each face supports 32 channels. 4kRF) and i can't seem to get any more energy into the system with energy acceptors. Disble chanels limit; And settings for all upper; Setting for conroller max size; Setting for amount of item and fluid per byte . 91. The CPU must be a cuboid, completely composed of the parts listed above; air or other blocks are not valid. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is. on an inbound basis to power the ME system. g. You make a me controller, a drive, and an access terminal, make a storage disk, place all machines next to each other, power the me controller with some form of mj or eu power. 2. 10 ae2 was just to annoying and it felt as if they ruined my favourite mid but thank you for this post cause I like the concept of everything ae2 stands for like the inscribed and meteorites to make things but growing certus and channels mad me think wtf did he do. In AE2 the ME Interface is basically instantaneous, so it should be limited by whatever is pushing the items into it. ME P2P Tunnels allow for very dense cable connections using Applied Energistics 2 channels. The ME crafting terminal from ae2 tutorial. Ah ok, so just a bigger set up I guess. . Aesthetically, the AE1 CPU was bigger, which made it look cooler as the centerpoint of a base IMO. Crafting CPU. Since AE2 is the only mod which uses AE, there isn't a good reason to make a 3rd party power converter to break it. ago. 180. Minecraft Version: 1. The questin i have is, if it is like this: the more surfaces the more…AE2 ME Network Freezing? This issue seems to keep coming up for me. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly. MEチェスト1. Controllers are a free-form Multiblock with various build rules. ) Things like ME Controllers, Inscribers or Crystal Growth Accelerators, do not use channels. Type : Item Stackable : Yes (64) Solid : Yes Transparent : No Affected by Gravity : No Emits Light : No Flammable : No Required Tool : The Cable Anchor is an item added by the Applied Energistics 2 mod. Applied Energistics is a Minecraft Mod which contains an advanced storage system called ME that lets you store items compactly and in the way you want, as well as do intricate automation. The maximum size of the connected block ix 7x7x7 (343 blocks). Connections are point-to-point - you can't connect more than 2 blocks together. Today we will. The Wireless Booster is an item added by the Applied Energistics 2 mod. 17. I wanted to build a 30x10xn (n = 3 or more layers) but after I place the 18th bl. Each subnetwork of 6 drives, ME Interface and ME Storage bus form an ad-hoc network without a controller. 3 Special Designs: Sub-networks & P2P Tunnels. 1]. 隣接した水での各種クォーツの種の成長を加速させる。. But in order for me to not pull my hair out and want to just not play until I finally hit some kind of epiphany in regards to this, I thought I'd ask for help in making a compact storage system of. Each block will use 10 + distance 2 AE/t (configurable)I dont really understand Ae2 nearly as much as i see most people do here on this sub, but Im trying to setup a large crafting grid of a 3x3x3 block, alternating between ME Interface's and Molecular Assemblers. An ME System is a system in Applied Energistics 2 that uses a ME Controller and a combination of other items found in Applied Energistics 2. 3 Controlling the Network . I just use a normal reactor with a huge capacitor bank to store power. R. Issues Source. I have a 5x5 big reactor supplying sufficient power. Additional Context. In this episode of Applied Energistics 2, we review how Smart and Dense Cables connect and interact with devices. P2P tunnels are always set to 1-to-n. The ME Controller's texture will change to display the stored energy level for network use. r/feedthebeast. With the channel mechanics that are currently in place, you can place a controller surrounded by 6 different color dense cables and then place 32 p2p connections on each cable, for a theoretical max of 6144 channels per controller, so why in the world would you ever need to have more than one. 4-rv6-stable-7. About Press Copyright Contact us Creators Advertise Developers Terms Privacy Policy & Safety How YouTube works Test new features NFL Sunday Ticket Press Copyright. Here is a little breakdown of how I wired it. The bus priority should be extremely high, set it to 10000 to be positive. Previously, my ME system was very stable; however after the upgrade, my ME controllers would randomly start to flicker. Having the 4 cables on the tops of them causes conflicts. networkfeatures {. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. I imagine one day I'll need those extra channels in which case I'll rip out this design and likely opt for the max size beast. like it doesnt exist. There are very few situations where putting an Export Bus and Storage Bus on the same inventory is actually useful (and infinite loops are a waste of both AE power and computer processing). 3. For the easiest way to automate inscribers, you need: (1) One ME interface. e. If dyed, cables will not connect to ones of a different color, which makes it easier to have many networks close together. I'm not gonna count but it looks like OP is using all 192 channels from a single controller block. The storage cell can be formatted before use to only accept certain items in the Cell Workbench. As I continue to dabble I may add in checking on the status of the requested jobs and bound the looping to when all requested jobs per loop-pass have been completed. You can attach the storage bus to the bottom of the drawer controller. You may be looking for ME Controller from Applied Energistics . That's 32x32 channels (1,024) going through a single dense cable line. r/feedthebeast. 채널은 한 ME 네트워크에 연결 가능한 최대 기계 수로, 기본적으론 8채널만 지원한다. Time to head for EMC a. CurseForge is one of the biggest mod repositories in the world, serving communities like Minecraft, WoW, The Sims 4, and more. Applied Energistics 2's ME Networks require Channels to support devices which use networked storage, or other network services. #2. Thats: 16 * 1024 * 1024 * 10 * 32 = 5'368'709'120 items per side of an ME controller. The ME Controller is the core machine required for any Applied Energistics network. 4mj/t for a ME drive filled with 4k vs 4. The item type cap is 61 *per drive*, so once you get 3-4 drives you're pretty much set. Welcome to the Applied Energistics Mod!This mod is all about digital storage and is much more complicated to it's counter part Refined Storage. Ah ok, so just a bigger set up I guess. All others (max. 5. Interior: 135 Tunnels giving 4320 channels, 5 sides on the outside are required to extract these tunnels. quartz cable wont connect networks, just power. One side of an ME controller can provide a bus for 32 systems. Technicaly it doesn't, but it's the only way to get the max channels out of many shapes of controllers. ME Controller • ME Covered Cable. Once the system detects named item 1 has finished it’ll put it and the next 8 components and named item 1 into the chest. Just out of pure curiosity, has anyone built or does anyone know that max number of channels that can be created from joined ME controllers? I know that the max size is 7x7x7, and that you can only have 3 blocks in a row without an air gap. Well, RS is an homage to AE1. Time to head for EMC a. AE2 rv3 beta6. I've attached leadstone pipe directly to the unit, but it didn't make a connection. ItsOswin 5 yr. B:PowerGen=. Applied Energistics 2. Now its working to the maximum potential it has. With storage-drawers there is the "drawer controller". AE2 network is small, 20 64K drives, 20 ME interfaces and 20 molecular assemblers but no patterns (issue happens with just controller). 2852;. 超圧縮し省スペース化を実現する大容量チェスト、洗練されたアイテム輸送等、 貯蔵&輸送 に特化した装置を追加する。. size unless you do something like the last pic. 128³ Spatial Storage. • 22 days ago. No crafting recipe for the AE2 version only chisel. It’s literally one output for a channel. More info below!You can support me and the channel! Read more here: my first base I set up a 5x5 big reactor which was my power source for rf machines and ae2. I have this issue right now where items I put in my main network through a terminal on that network, or my wireless terminal synced with the main network are ending up in the me drive on subnetwork 2. The controller is 32 channels per face, so 1 controller can output 192 channels total if you use all 6 faces. toml): DisableChannels (initially -> false) - disables channel restrictions; ControllerLimits. I then use an Ender IO power monitor to turn the reactor on and off. This a max amount of 314. One side of an ME controller can provide a bus for 32 systems. . Or so I heard. 57. I don't hear people screaming "Spread your drives! Spread your drives!" so quite possibly AE2 has some other storage solution to prevent this. 0 alpha that provides wireless connections. An ME controller supports up to 32 channels per block face, but you must use a dense cable to utilize all 32 channels and then branch them off with normal cables as you cannot connect a machine to a dense cable directly. Whenever you have more than 8 devices in a network, an ME Contr. 12. ---> which I have all 3 controller blocks connected. But depending on the choosen balance between less or more effort the actual amount max might vary between values like 32, 128, 512 or 1024. You configure the connections by using the ME Bus Memory Card; First Shift+Right Click the input to save it on your memory card, then simply right click the diffrent outputs to store the input onto the. Setting the Storage Bus to a high priority should be all you need to ensure items always go there first. Yes i have a controller (its AE2 btw) I already have 3 cards per bus, that didnt work. Now for the Storage Drawer Solution, you'll need the following for each module: 1 Storage Drawer, 1 ME Storage Bus, 1 Storage Drawers Void Upgrade. Normally in the inside of a corner you can't get 32 channels out of each face as if you place a cable there it'll connect to both faces and only let 32 channels through itself, wasting anywhere from 32 channels in a regular corner, and 128 in. 2. Feed The Beast Wiki. Controller mutliblock has to fit within a 7x7x7 - again, not too bad. I have an Empowerer from Actually Additions 2, but it seems to be fighting for bandwidth with my Molecular Assemblers. But you have to supply it with one of the following forms. 並列処理機構を組むにあたって重要な部分になります。. Each one of those can handle a several more channels. The Compacting Drawer is a block added by Storage Drawers to quickly convert items between Storage Blocks and their original form. Yes, it's not too large, so the time it takes to catch up is 10 seconds at the very most. 5 5.入出力端末を作る. This configuration seems to allow me to have as much as 9408 channels and i know that i don't really need this many, but it's fun to reach the limits sometimes. The Drawer Controller can coordinate the function of all connected drawers within a 12 block range along any axis. The maximum size of the connected block ix 7x7x7 (343. 2. . If there's "Extra Cells 2" in your pack, the biggest storage cells are 16M (instead of 64k). gradle. The problem is as of now you can get 2304 channels in a 3x3 with all the centers punched out so it’s hard to beat that. . Just put one ME Storage Bus on the Drawer Controller. I wanted to build a 30x10xn (n = 3 or more layers) but after I place the 18th bl. Now you need to get named item 1 into the second inscriber which contains a different name plate press that’ll turn it into named item 2. In the case of AE2's assemblers, that's probably going to mean a controller, a single assembler block, a memory block, and a hard drive; but again, I'm guessing. 11. one ME Access Terminal or ME Crafting Terminal if you have chosen an ME Drive as your first Storage. They are usually very limited in scope and rarely directly accessed by the player (mostly for automation). Each device takes one channel. When I expanded it I searched for a way to have 32 interfaces on one ME Dense Cable. Also, AE2 uses priorities intelligently. At its most basic, the ME Controller is just a single block, however, it can be expanded to the size of a 7x7x7 multiblock if you so wish (with some restrictions). The amount of Coal Ore produced by a Void Ore Miner is obscene. The size of the ME Controller must be within 7x7x7; else it will turn red. You can make that thing look like a tree, with p2ps holding 8 channels each everywhere. total size 29x29x9. I just use a normal reactor with a huge capacitor bank to store power. . 2) Wire the 5 p2p ends from the other side, the top 2, and the top 1 on the back side. An updated guide on large ME controllers and P2P networking. Seems weird that it wont try to take a different route that's the same length to the controller. It is used to interact with a group of drawers. . Corner blocks and wall edges must be ME Assembler Containment Walls. them outside the network. All Spatial Pylons must be either connected with cable or via a QNB, and on the same network. You may be looking for ME Controller from Applied Energistics . . However, you will need to reconnect a P2P bus (per dense cable). I think this might give more channels per controller (128 per controller vs 124) but I might be wrong. AppliedEnergistics / Applied-Energistics-2 Public. We have the ME Controller from applied energistics 2 for our minecraft mod tutorial. This article is about ME Controller from Applied Energistics 2 . Now, I've crafted a couple of CM and CM tunnels but the AE2 cables didn't connect with the side of the cube neither inside or outside. It accepts energy in from most sources, such as EU and MJ and provides it to the machines connected to it. 55. It has to be touching the drawer bank. The AE2 Stuff Network Visualisation Tool obviates the need for a mess of colored cables, too. Flammable. Neverthless I do not see many arguments to convince me about this option. One actively pulls items, one passively accepts items. 2Applied Energistics 2. Almost right. A ME Controller can have 2 adjacent blocks in at most 1 axis; if a block violates this rule, it will disable. MEコントローラ (ME Controller) スカイストーンブロック:4+純粋なフルーシュクリスタル:4+上級プロセッサ:1. Yeah what you found is actually a main part of "normal" ae2 progression, the ad hoc system. One ME P2P tunnel may pass along 32 channels of data using just a normal covered or smart cable, and up to 4 PAIRS of tunnel nodes may exist on such a cable (8 total nodes for one channel each). I already have dense cables running through my entire system, so that's not going to be a problem. Join. Networks without an ME Controller are considered Ad-Hoc and can support up to 8 channels of device usage. This allows the mod (Applied Energistics 2) to accept multiple forms of power, but not be a totally broken power converter. It will use only one channel. 14.